江门ABB伺服驱动器MFE180-04AN-031A-4通电报警30013故障维修
ABB驱动器故障代码30013 :Communication has been lost to the FieldbusOption (_ecFIBLDBUS_OPTION_COMMUNICATION_LOST)
30013通信已丢失到现场总线选项(_EcFIBLDBUS_OPTION_CONICATION_Lost)
Communication between the MotiFlex e100 and thefieldbus option has been lost for some reason, e.g. due to awatchdog time-out. An auto reset of the feldbus option will beattempted, but only if the option was previously in a workingstate. lf the ernor wasgenerated during confguration and setup ofthe fieldbus option, then auto reset will not take place and so theuser may need toissue a manual reset using BUSRESET.
MotiFlex e 100
与现场总线选项之间的通信由于某些原丢失,例如由于看门狗超时。将尝试自动重置feldbus选项,但前提是该选项以前处于工作状态。如果ERNOR是在现场总线选项的混合和设置过程中生成的,那么自动重置将不会发生,用户可能需要使用BUSRESET发出手动重置。
AL001 过电流 主回路电流值超越电机瞬间大电流值1.5 倍时动作
AL002 过电压 主回路电压值高于规格值时动作
AL003 低电压 主回路电压值低于规格电压时动作
AL004 电机匹配异常 驱动器所对应的电机不对
AL005 回生异常 回生控制作动异常时动作
AL006 过负荷 电机及驱动器过负荷时动作
AL007 过速度 电机控制速度超过正常速度过大时动作