江门发那科伺服驱动器维修 A06B-6130-H002报警SV0401维修
发那科伺服驱动器报警SV0401:伺服准备就绪信号断开
报警原因:伺服放大器伺服准备就绪信号(VRDY)尚未被置于ON 时,或在运行过程中被置于 OFF 时发生此报警。
解决方案:
1)排查诊断号358;
例如:诊断358=1441,转换为二进制为10110100001,从第5位开始排查,第6位为0,确认应排查急停相关接线等。
2)伺服放大器或者轴卡硬件损坏,更换硬件。
SV0403 硬件/软件 不匹配
报警原因:轴卡与伺服软件组合不正确,可能的原因有:
1)没有提供正确的轴卡;
2)闪存中没有安装正确的伺服软件。
发那科伺服驱动器维修报警故障代码: 400,401 ,402 ,403,404 ,405 ,406,408,409,,410 ,420 ,430 ,411 ,421,431,,413,415,423,433,414,424,434,425,435,416,426,417,420,421,422,423,427,430,431,432,433,434,435,436,437,438,439,440,441,442,443,444,445,446,447,448,449,453,456,457,458,459,460,461,462,463,464,465,466,467,468,490,491,494,495, 600,601 ,602 ,603 ,604 ,605 ,606 ,607700,701,704,740,741,742,749,750,5134,5135,5136,5137,5197,5198,900,910 发那科系统报: 911,912,913,914,915,916,917,918,918,919,920 ,921 ,922,926,930 ,935,940 ,941,945,946 ,950 ,951,960 ,970, 912,972,973,974,975,976,998 发那科系统开机状态8,7,6,5,4,3,2,1,0,为系统正在开机的状态